Advantages SBC ADV Plus Medium and HI-Power
* Three stage IUoU battery charging
* Multiple outputs in order to charge more groups of batteries (internal battery isolator diodes)
* Differentiated charging for liquid electrolite or gel batteries
* Integrated fuses inside the battery chargers (one for each output)
* Thermal battery protection (with optional sensors)
* Ability of providing full output power with low supply voltage
* The possibility of using the battery charger as a power supply without batteries
* Low residual fluctuation on output (ripple lower than 30 mV RMS)
* Compatible with every kind of generator
* Capable of operating in a wide range of ambient temperatures
* Variable speed for the cooling fan
* High-technology control panel
* Automatic and manual half power mode (with optional CAN terminal)
* CAN BUS interface for data transfer
* Current sharing (only HI-Power)
Protections:
* Reverse polarity (with internal fuses)
* Overload
* Output short circuit
* Overvoltage in output
* Overheating
* Battery overtemperature (with optional sensors)
SBC 300 ADV PLUS FR
Max output current (1) 30 A
Charge absorption voltage 14.1 Vdc (14.4 Vdc GEL)
Charge float voltage 13.5 Vdc (13.8 Vdc GEL)
Number of outputs (2) 3
Supply voltage 280÷83 Vac with power reduction under 97 Vac
Frequency 45 ÷ 66 Hz
Max absorption (230 Vac) (3) 2,5 A
Max absorption (115 Vac) (3) 5,1 A
Power factor (cos ϕ) 1
Operating temperature -4°F ÷ +158°F, with power reduction over +122°F
Cooling Forced, by variable speed cooling fan
Dimensions W x H x D - inch 10"23/32 x 13"1/8 x 5"
Weight - lb 9,26 lb